Quality Saves Time: Why Contour Accuracy Drives Real Efficiency in Radiotherapy

Two clinicians sitting at a desk looking at Contour+ on their computer screens

In radiation therapy planning, delineating organs at risk (OARs) and target volumes is one of the most labor-intensive steps in the clinical workflow. Manual contouring requires clinicians to trace complex anatomical boundaries slice by slice. This activity can consume over 90 minutes per patient, depending on the number and complexity of delineated volumes. While artificial intelligence (AI) auto-contouring eliminates the blank-page drawing phase, it does not remove the need for human oversight. Instead, it shifts clinical effort from manual creation to reviewing and editing generated structures. Consequently, the net time saved depends on initial contour quality: the fewer corrections a clinician must make, the less time goes into review.

Evaluating auto-contouring tools solely by their raw generation speed overlooks the clinical bottleneck. An algorithm that generates a structure set in under two minutes offers little practical relief if inaccurate boundaries force radiation oncologists or dosimetrists to spend 30 minutes deleting and redrawing slices. In daily practice, inference time occurs in the background, whereas manual editing consumes scarce clinician hours.

To capture true workflow efficiency, quality must be measured beyond traditional geometric overlap metrics. Dice similarity coefficients (DSC) and 95th-percentile Hausdorff distances (HD95) quantify spatial agreement against reference contours, but are not always accurately correlated with actual clinical workload. A minor boundary error across several slices in a clinically relevant region may barely lower a high Dice score yet still require tedious slice-by-slice manual adjustments. A meaningful evaluation therefore pairs geometric indices with Added Path Length (APL), qualitative acceptability scores, the proportion of structures accepted without modification, and total hands-on editing time.

The possibility to customize which structures are generated, to adjust their names and colors, helps the medical team to shorten even more the interval from receiving the AI-generated structure set to the final version used for treatment planning. These features, together with the possibility of combining structures, overlapping or subtracting them, make Contour+ a versatile and precise tool in clinicians’ hands.

Peer-reviewed studies that evaluated MVision AI Contour+ explicitly demonstrate how high baseline accuracy translates into measurable time reductions:

  • Strolin et al. (“Frontiers in Oncology”, 2023): Evaluating MVision AI across 111 patients, researchers found that median manual delineation took 25.0 minutes compared to 2.3 minutes for automated segmentation plus 10.0 minutes for manual correction—a statistically significant reduction in overall contouring time (p < 0.001). Notably, 87% of contours were rated “well done” or “very well done,” requiring minimal or no editing (1).
  • Doolan et al. (“Frontiers in Oncology”, 2023): Benchmarking five commercial AI solutions across 80 breast, head-and-neck, lung, and prostate cases, MVision achieved a median vDSC of 0.88 across all structures. Even after accounting for manual correction time, MVision yielded an average net time saving of 43.6 minutes per patient, peaking at over 74 minutes in complex head-and-neck cases (2).
  • Langmack et al. (“British Journal of Radiology”, 2025): Auditing the clinical rollout of MVision AI, the authors reported that 80% of evaluated sites required no or only minor edits, enabling median planning turnaround times to drop by 5.5 working days for breast and 9 working days for prostate radiotherapy (3).
  • Meixner et al. (“Clinical and Translational Radiation Oncology”, 2024): Comparing automated models for postoperative breast and nodal targets, the ESTRO-based MVision model achieved the highest clinical usability, with 78% of cases requiring minor or no adjustments (4).
  • Warren S et al (“IPEM-Translation”, 2023): Specifically assessed the impact of using MVision AI on the clinical workflow. Not only were 76% of all breast lymph node volumes considered acceptable as-is or with minor edits in the offline evaluation phase, but 89% of patients planned with AI-guided field placement had treatment plans and dose distributions accepted without modifications in the prospective phase evaluation (5).
  • Mason J et al (“phiRO”, 2025): Evaluated the amount of editing of MVision AI Contour+ generated structures during 18 months of clinical use. They observed that editing decreased after 2 months, reaching a steady state, with approximately 40% of contours requiring no editing. Variations in editing were due to model updates, as well as adaptation of local contouring practice and reduced editing of areas with no clinical significance (6).

MVision AI builds Contour+ around the principle that “Quality saves time”, rather than optimizing purely for inference speed. Contour+ uses guideline-based segmentation trained on standardized international consensus protocols (such as ESTRO and RTOG) to deliver consistent, anatomically faithful structures that minimize downstream editing.

When evaluating auto-contouring solutions, clinics should look past headline generation speeds. Decision-makers should prioritize clinical acceptability rates, unedited acceptance shares, APL, and real-world editing times across complex anatomical sites, ensuring the software genuinely frees clinical capacity rather than shifting labor from drawing to correcting.

References

  1. Strolin, S., Santoro, M., Paolani, G., Ammendolia, I., Arcelli, A., Benini, A., Bisello, S., Cardano, R., Cavallini, L., Deraco, E., Donati, C. M., Galietta, E., Galuppi, A., Guido, A., Ferioli, M., Laghi, V., Medici, F., Ntreta, M., Razganiayeva, N., … Strigari, L. (2023). How smart is artificial intelligence in organs delineation? Testing a CE and FDA-approved deep-learning tool using multiple expert contours delineated on planning CT images. Frontiers in Oncology, 13. https://doi.org/10.3389/fonc.2023.1089807
  2. Doolan, P. J., Charalambous, S., Roussakis, Y., Leczynski, A., Peratikou, M., Benjamin, M., Ferentinos, K., Strouthos, I., Zamboglou, C., & Karagiannis, E. (2023). A clinical evaluation of the performance of five commercial artificial intelligence contouring systems for radiotherapy. Frontiers in Oncology, 13. https://doi.org/10.3389/fonc.2023.1213068
  3. Langmack, K. A., Alexander, G. G., Gardiner, J., McKenna, A., & Shawcroft, E. (2025). An audit of the impact of the introduction of a commercial artificial intelligence-driven auto-contouring tool into a radiotherapy department. British Journal of Radiology, 98(1167), 375–382. https://doi.org/10.1093/bjr/tqae255
  4. Meixner, E., Glogauer, B., Klüter, S., Wagner, F., Neugebauer, D., Hoeltgen, L., Dinges, L. A., Harrabi, S., Liermann, J., Vinsensia, M., Weykamp, F., Hoegen-Saßmannshausen, P., Debus, J., & Hörner-Rieber, J. (2024). Validation of different automated segmentation models for target volume contouring in postoperative radiotherapy for breast cancer and regional nodal irradiation. Clinical and Translational Radiation Oncology, 49, 100855. https://doi.org/10.1016/j.ctro.2024.100855
  5. Warren, S., Richmond, N., Wowk, A., Wilkinson, M., & Wright, K. (2023). AI segmentation as a quality improvement tool in radiotherapy planning for breast cancer. IPEM-Translation, 6–8, 100020. https://doi.org/10.1016/j.ipemt.2023.100020
  6. Mason, J., Doherty, J., Robinson, S., de la Bastide, M., Miskell, J., & McLauchlan, R. (2025). Auditing the clinical usage of deep-learning based organ-at-risk auto-segmentation in radiotherapy. Physics and Imaging in Radiation Oncology, 33, 100716. https://doi.org/10.1016/j.phro.2025.100716
Written by
Monica-Emilia Chirilă
Monica-Emilia Chirilă
Radiation Oncologist

Monica is a Radiation Oncologist working in a Romanian private clinic which is part of a European Network. She is also the Managing Editor of the Journal of Medical and Radiation Oncology (JMRO), an independent researcher and a medical journalist. Her main research focus is on breast cancer, prostate cancer, education, patient reported outcomes, and AI use in Radiation Oncology.